Utilizing the large specific surface area and high adsorption capacity of activated carbon, adsorption treatment of low-to-medium concentration organic waste gas is an extremely effective treatment method. Pollutants in the organic waste gas are adsorbed inside the activated carbon, and clean gas is discharged, thus achieving purification.
This method organically combines an adsorption concentration unit and a thermal oxidation unit. It is mainly suitable for organic waste gas with low concentrations that are not suitable for direct combustion, catalytic combustion, or adsorption recovery methods, especially for large-volume treatment applications, where satisfactory economic and social benefits can be obtained. After adsorption purification and desorption, the organic waste gas is converted into a small volume, high-concentration stream, which is then subjected to thermal oxidation treatment, and the heat released from the combustion of organic matter is effectively utilized.
Application areas: organic chemical industry, pharmaceuticals, paint production, surface coating, petroleum, packaging and printing, etc.
The process uses a combination of activated carbon adsorption, hot air desorption, and catalytic combustion to purify organic waste gas, proceeding in three working stages:
First, the working process utilizes the multi-porous structure, huge surface tension, and large adsorption capacity of activated carbon to adsorb organic solvents in the waste gas, achieving a purification efficiency of over 95%, thus purifying the discharged waste gas.
Second, due to the limited adsorption capacity of activated carbon, after a period of adsorption, when the activated carbon reaches saturation, adsorption stops. At this point, the organic matter has been concentrated within the activated carbon. After the activated carbon is saturated, the organic solvents adsorbed on the activated carbon are desorbed using a hot air stream at a certain concentration ratio and sent to the catalytic combustion bed.
Third, the high-concentration organic waste gas entering the catalytic combustion bed is further heated and then oxidized and decomposed under the action of a catalyst, converting it into carbon dioxide and water. The heat released from the decomposition is recovered by a high-efficiency heat exchanger and used to heat the high-concentration organic waste gas entering the catalytic combustion bed.
In the adsorption concentration-catalytic combustion method, the equipment uses multiple gas paths for continuous operation, and multiple adsorption beds can be used alternately. After the three working processes reach self-equilibrium after a certain period of operation, the desorption and catalytic decomposition processes do not require external energy for heating. 1) Pre-treatment Stage
The pre-treatment stage utilizes a packed-bed spray scrubbing tower. The scrubbing liquid is selected to neutralize acidic gases with an alkaline solution, or a dry filter is used to filter out dust particles.
2) Activated Carbon Adsorption Stage
After the pre-treatment, the waste gas is introduced into the activated carbon adsorption/desorption tower for adsorption treatment. Organic gases are adsorbed onto the surface of the activated carbon through its micropores, removing organic substances from the waste gas and achieving the effect of purifying the gas.
3) Activated Carbon Desorption Stage
When the adsorption bed is saturated, the desorption and adsorption valves are switched, and the desorption fan is started to desorb the saturated adsorption bed. The fresh air for desorption is first heated by a heat exchanger and an electric heating chamber at the fresh air inlet, heating the fresh air to approximately 120°C before entering the activated carbon bed. Upon heating, the solvent adsorbed by the activated carbon evaporates.
4) Catalytic Combustion Stage
The waste gas desorbed from the activated carbon has a low flow rate and high concentration. It is sent to a heat exchanger by a fan, then enters a preheater. Under the heating effect of the electric heater, the gas temperature is raised to approximately 200-300°C before entering the catalytic combustion bed. This causes the organic waste gas to undergo flameless combustion under the action of the catalyst, being oxidized into CO2 and H2O, and simultaneously releasing a large amount of heat energy. As the gas temperature further increases, this high-temperature gas preheats the untreated organic gas through the heat exchanger before the catalytic combustion chamber. The gas exiting the heat exchanger then passes through the heat exchanger at the fresh air inlet to heat the fresh air for desorption. After the two heat exchangers are operating normally, the electric heating equipment can be stopped, saving energy. Finally, the gas is discharged into the atmosphere through a chimney. The exhaust gas, containing organic components with boiling points of toluene (110.6℃) and xylene (138-144℃), is sent to an adsorption bed for desorption. The high-concentration organic exhaust gas (which can be concentrated 10-20 times) is then heat-exchanged with the hot exhaust gas from combustion in a heat exchanger for preheating before being sent to the combustion chamber. In the combustion chamber, after reaching the ignition temperature, the organic compounds are oxidized and decomposed into harmless CO2 and H2O by a catalyst. The combustion exhaust gas, after being cooled to 180-200℃ through heat exchange with the desorbed gas, is used for desorption. The excess exhaust gas is discharged through the exhaust stack.
Multiple adsorption beds are used in rotation for adsorption and desorption regeneration, switching between adsorption and desorption for continuous operation (working time can be adjusted according to the company's production situation). This project is designed for an exhaust gas concentration of 100 ppm, and the concentrated organic exhaust gas concentration can reach over 5000 mg/m³. After the burner is started and heated to the ignition temperature by electric heating, self-combustion can be maintained.
A direct discharge port is provided at the gas inlet, controlled by an electric valve. When the equipment is not working, the direct discharge port remains open. If the adsorption device fan malfunctions, the direct discharge valve automatically opens for maintenance. Catalytic purification is used for desorption and regeneration. Flame arresters are installed at both the inlet and outlet of the device, and the entire system is controlled by a PLC.